Sterile items are stored in a clean, controlled, positive-pressure area with limited traffic. Shelving should keep items at least 8 to 10 inches above the floor, at least 18 inches below the ceiling or sprinkler heads, and at least 2 inches from outside walls. Items should be handled as little as possible and kept away from moisture and dust.

On the CRCST exam

Know the clearance numbers and why the bottom shelf must not sit on the floor.

Exam domain: Sterile Storage, Transport & Inventory (about 9% of the exam)